DC servo motor question

General Metalworking - All aspects of working with metal. 

Bookmark this page:  YahooMyWeb Yahoo!  Google Google  Windows Live Favorites Windows Live  del.icio.us del.icio.us  digg digg  Add to Netscape Netscape
Subject Author Date
DC servo motor question etpm 10-03-2008
Posted by on October 3, 2008, 11:45 am
Please log in for more thread options


I've got a couple DC servo motors that are in great shape but old
enough that Electro-Craft no longer has any info on them. So I would
like to know if there is a way to figure out what max voltage and
current might be. Can using the motor as a generator be used as a way
to determine the approximate proper voltage and current?
Thanks,
Eric

Posted by Ned Simmons on October 3, 2008, 12:36 pm
Please log in for more thread options


On Fri, 03 Oct 2008 15:45:37 GMT, etpm@whidbey.com wrote:

>I've got a couple DC servo motors that are in great shape but old
>enough that Electro-Craft no longer has any info on them. So I would
>like to know if there is a way to figure out what max voltage and
>current might be. Can using the motor as a generator be used as a way
>to determine the approximate proper voltage and current?

I'd first compare the motor to motors of similar size and construction
to get an estimate of torque rating and max RPM.

Then experiment using the relationships
Ke = RPM/volt
Kt = lb*in/amp
to get values for Ke and Kt.

Either rotating the motor at a known speed and measuring the output
voltage, or powering the motor with a known voltage and measuring RPM
will give you Ke.

To determine Kt you'll need to control torque and measure current, or
vice versa. The easiest way would probably be to drive the motor with
an adjustable current source with a torque arm and weight attached to
the shaft. Adjust the current to balance the weight with the arm
horizontal.

Keep in mind that DC motors will have both a continuous and a peak
current rating. The continuous current is mainly a function of winding
resistance and the ability of the motor to dissipate heat. The ratio
between continuous and peak current is generally an indication of
magnet material and the resistance of the magnets to demagnetization
as a result of high current in the windings. You might see a ratio of
3:1 in low end motor, while a high performance, low inertia motor
might be as high as 7:1 or more.

--
Ned Simmons

Posted by on October 4, 2008, 1:27 am
Please log in for more thread options


wrote:

>On Fri, 03 Oct 2008 15:45:37 GMT, etpm@whidbey.com wrote:
>
>>I've got a couple DC servo motors that are in great shape but old
>>enough that Electro-Craft no longer has any info on them. So I would
>>like to know if there is a way to figure out what max voltage and
>>current might be. Can using the motor as a generator be used as a way
>>to determine the approximate proper voltage and current?
>
>I'd first compare the motor to motors of similar size and construction
>to get an estimate of torque rating and max RPM.
>
>Then experiment using the relationships
>Ke = RPM/volt
>Kt = lb*in/amp
>to get values for Ke and Kt.
>
>Either rotating the motor at a known speed and measuring the output
>voltage, or powering the motor with a known voltage and measuring RPM
>will give you Ke.
>
>To determine Kt you'll need to control torque and measure current, or
>vice versa. The easiest way would probably be to drive the motor with
>an adjustable current source with a torque arm and weight attached to
>the shaft. Adjust the current to balance the weight with the arm
>horizontal.
>
>Keep in mind that DC motors will have both a continuous and a peak
>current rating. The continuous current is mainly a function of winding
>resistance and the ability of the motor to dissipate heat. The ratio
>between continuous and peak current is generally an indication of
>magnet material and the resistance of the magnets to demagnetization
>as a result of high current in the windings. You might see a ratio of
>3:1 in low end motor, while a high performance, low inertia motor
>might be as high as 7:1 or more.
>
>--
>Ned Simmons
Thanks for the reply Ned. These motors came from a lathe that
originally had a Bandit control. Later these same lathes were equipped
with a Fanuc 5T control and Fanuc motors. If I short the wires on the
Electro-Craft motors and spin the shaft by hand there is a lot of
drag, but the Fanuc motors have very little drag when the shaft is
spun by hand. I'll try powering them both with the same voltage and
compare speed and then I'll measure the current drawn with the torque
arm setup you described.
Thanks Again,
Eric

Posted by on October 5, 2008, 4:49 pm
Please log in for more thread options


On Sat, 04 Oct 2008 05:27:58 GMT, etpm@whidbey.com wrote:

>wrote:
>
>>On Fri, 03 Oct 2008 15:45:37 GMT, etpm@whidbey.com wrote:
>>
>>>I've got a couple DC servo motors that are in great shape but old
>>>enough that Electro-Craft no longer has any info on them. So I would
>>>like to know if there is a way to figure out what max voltage and
>>>current might be. Can using the motor as a generator be used as a way
>>>to determine the approximate proper voltage and current?
>>
>>I'd first compare the motor to motors of similar size and construction
>>to get an estimate of torque rating and max RPM.
>>
>>Then experiment using the relationships
>>Ke = RPM/volt
>>Kt = lb*in/amp
>>to get values for Ke and Kt.
>>
>>Either rotating the motor at a known speed and measuring the output
>>voltage, or powering the motor with a known voltage and measuring RPM
>>will give you Ke.
>>
>>To determine Kt you'll need to control torque and measure current, or
>>vice versa. The easiest way would probably be to drive the motor with
>>an adjustable current source with a torque arm and weight attached to
>>the shaft. Adjust the current to balance the weight with the arm
>>horizontal.
>>
>>Keep in mind that DC motors will have both a continuous and a peak
>>current rating. The continuous current is mainly a function of winding
>>resistance and the ability of the motor to dissipate heat. The ratio
>>between continuous and peak current is generally an indication of
>>magnet material and the resistance of the magnets to demagnetization
>>as a result of high current in the windings. You might see a ratio of
>>3:1 in low end motor, while a high performance, low inertia motor
>>might be as high as 7:1 or more.
>>
>>--
>>Ned Simmons
>Thanks for the reply Ned. These motors came from a lathe that
>originally had a Bandit control. Later these same lathes were equipped
>with a Fanuc 5T control and Fanuc motors. If I short the wires on the
>Electro-Craft motors and spin the shaft by hand there is a lot of
>drag, but the Fanuc motors have very little drag when the shaft is
>spun by hand. I'll try powering them both with the same voltage and
>compare speed and then I'll measure the current drawn with the torque
>arm setup you described.
>Thanks Again,
>Eric



PM servo motors are designed for equal performance in

either direction of rotation. This means that they are

necessarily low speed (<5000 Rpm) machines because the brush

angle cannot be offset to reduce high speed sparking. Typical

rated power is at 3,000 RPM. so the voltage needed to produce

3,000 RPM should be pretty close to the motor rated voltage.


Check the stalled resistance. Ohmeter readings can be very

unreliable - measure the effective resistance by monitoring the

terminal voltage when passing 1 amp or so through a stalled

motor

.
http://xs.to/xs.php?h=xs432&d=08400&f=motor_power_rating_-002155.jpg


shows the average relation between motor rated power,rated

voltage and typical winding resistance. It will not of course

give a precise answer because individual motor designs can be far

from average but it will be a LOT better than eyeball estimates.


For a closer figure you need to guesstimate the motor

maximum current. Copper has a temperature co-efficient of 0.4%

/deg C. If you now increase the stalled current (in stages to

allow time for the temperature to stabilise) until the measured

R increase by 30% the winding temperature will be about 100 deg

C which is pretty safe - High temperature servo motors can

withstand up to 150 deg C. This process is not as long winded

as it sounds - you can usually get a pretty close estimate with

no more than two trial currents. For best accuracy use the

brushes to feed the current through the armature and measure the

voltage drop directly on the relevant commutator segments.

Jim

Posted by Bob Engelhardt on October 6, 2008, 8:04 pm
Please log in for more thread options


pentagrid@yahoo.com wrote:
> ...
> For a closer figure you need to guesstimate the motor
> maximum current. ...
> If you now increase the stalled current ... until the measured
> R increase by 30% the winding temperature will be about 100 deg
> C ...

Jim - thanks for the great info. Question about the max current
process: if the motor is stalled during this test, you'd only be
heating one winding - is that going to give a good current value that
can be used when all windings are in use (running)? In other words, the
current required to give a certain temp depends upon the cooling and the
cooling will be different when running.

Thanks,
Bob
---
Nota for President

Similar ThreadsPosted
servo motor control ?? September 4, 2007, 9:41 am
Manufacturer and Suppliers of AC Servo Drives, AC Servo Brushless Motors and PLC April 5, 2007, 7:33 am
Motor Question... July 31, 2006, 9:21 am
Re: Motor question November 18, 2007, 1:31 am
Re: Motor question November 18, 2007, 1:58 am
Re: Motor question November 18, 2007, 2:09 am
Re: Motor question November 18, 2007, 11:20 am
Another DC motor question October 5, 2008, 7:36 pm
WTD: Servo Table Feed July 23, 2006, 12:36 pm
X - Y servo positioning table November 13, 2006, 4:57 pm

Contact Us | Privacy Policy

XML SitemapXML Sitemap