Posted by on March 25, 2008, 10:29 pm
Please log in for more thread options
Hello,
The electrode I have been using is a 3/32" 2% Thoriated. Do you think
the Dynasty 200 DX unit is malfunctioning? Here are the specifics:
Input power is Single Phase 220VAC on 50Amp circuit (Upgraded from
30Amp circuit)
DC Polority
Measured -16VDC with the DCEN process
Argon Gas
Verified plug wiring.
Verified torch and ground connections
Diamondback torch
Coolmate 3
Peak A set to 70.
Thanks!
|
|
Posted by Don Foreman on March 26, 2008, 1:43 am
Please log in for more thread options
On Tue, 25 Mar 2008 19:29:08 -0700 (PDT), daluds@gmail.com wrote:
>Hello,
>
>The electrode I have been using is a 3/32" 2% Thoriated. Do you think
>the Dynasty 200 DX unit is malfunctioning? Here are the specifics:
>
>Input power is Single Phase 220VAC on 50Amp circuit (Upgraded from
>30Amp circuit)
>DC Polority
>Measured -16VDC with the DCEN process
>Argon Gas
>Verified plug wiring.
>Verified torch and ground connections
>Diamondback torch
>Coolmate 3
>Peak A set to 70.
>
>Thanks!
It's certainly possible that your machine isn't working right. 16
volts sounds quite low even with an arc running and way low for open
circuit voltage. That sounds more like a MIG machine at a low
setting.
|
|
Posted by on March 26, 2008, 10:06 pm
Please log in for more thread options Thanks for all the help! Finally figured out the problem! The Dynasty
200 DX machine works great. The only problem was the guy holding the
torch. With some lessons from a very experienced professional all is
working. The most significant problem was the incorrect face shield
for the job. Its so much different than MIG or ARC welding. Plan to
buy new face shield with fixed gold shade of 11 with magnifier
followed by more hands on practicing.
Luds
|
|
Posted by Bruce L. Bergman on March 27, 2008, 12:17 am
Please log in for more thread options On Wed, 26 Mar 2008 19:06:34 -0700 (PDT), daluds@gmail.com wrote:
>Thanks for all the help! Finally figured out the problem! The Dynasty
>200 DX machine works great. The only problem was the guy holding the
>torch. With some lessons from a very experienced professional all is
>working. The most significant problem was the incorrect face shield
>for the job. Its so much different than MIG or ARC welding. Plan to
>buy new face shield with fixed gold shade of 11 with magnifier
>followed by more hands on practicing.
>
>Luds
IOW the whole problem was a loose nut behind the torch.
Been there, Done that, Have the book, Saw the movie, the book was
better, the movie was totally mis-cast...
--<< Bruce >>--
|
|
Posted by Don Foreman on March 27, 2008, 3:35 am
Please log in for more thread options On Wed, 26 Mar 2008 19:06:34 -0700 (PDT), daluds@gmail.com wrote:
>Thanks for all the help! Finally figured out the problem! The Dynasty
>200 DX machine works great. The only problem was the guy holding the
>torch. With some lessons from a very experienced professional all is
>working. The most significant problem was the incorrect face shield
>for the job. Its so much different than MIG or ARC welding. Plan to
>buy new face shield with fixed gold shade of 11 with magnifier
>followed by more hands on practicing.
>
>Luds
The best investment by far you can make at this point is an autodark
welding mask.
Gunner can recommend best buys.
I've been welding for decades now, did plenty of it by head-nodding.
Then I got an autodark. If my Jackson autodark crapped out,
replacing it would be high priority.
|
| Similar Threads | Posted | | must sell Miller TIG Welder - Dynasty 200 DX AC/DC TIG/Stick | September 29, 2008, 6:53 pm |
| Welding Tungsten | February 10, 2007, 10:36 pm |
| tungsten alloy rod | October 24, 2007, 4:07 pm |
| Tungsten Grinding | April 20, 2008, 8:41 pm |
| Tungsten Alloy Scrap Value? | November 11, 2006, 9:55 am |
| Threading Tungsten metal rod | January 24, 2008, 6:31 pm |
| Tungsten wear life? | September 28, 2008, 3:31 pm |
| I want to buy a solid piece of pure tungsten, 3 to 15 lbs. | October 19, 2007, 2:37 pm |
| Melting aluminum | October 5, 2007, 2:23 am |
| Re: Melting down wingers | October 5, 2008, 8:21 pm |
|
|
>
>The electrode I have been using is a 3/32" 2% Thoriated. Do you think
>the Dynasty 200 DX unit is malfunctioning? Here are the specifics:
>
>Input power is Single Phase 220VAC on 50Amp circuit (Upgraded from
>30Amp circuit)
>DC Polority
>Measured -16VDC with the DCEN process
>Argon Gas
>Verified plug wiring.
>Verified torch and ground connections
>Diamondback torch
>Coolmate 3
>Peak A set to 70.
>
>Thanks!